solar-toolkit/inverter/types.go

178 lines
10 KiB
Go

package inverter
import (
"fmt"
"time"
"golang.org/x/exp/constraints"
)
type numeric interface {
constraints.Integer | constraints.Float
}
type (
Power float64
Voltage float64
Current float64
Energy float64
Frequency float64
Temp float64
)
func newPower[T numeric](v T) Power { return Power(float64(v)) }
func newVoltage[T numeric](v T) Voltage { return Voltage(float64(v) / 10.0) }
func newCurrent[T numeric](v T) Current { return Current(float64(v) / 10.0) }
func newFrequency[T numeric](v T) Frequency { return Frequency(float64(v) / 100.0) }
func newTemp(v int16) Temp { return Temp(float64(v) / 10.0) }
func newEnergy[T numeric](v T) Energy {
f := float64(v)
if f == -1 {
return 0
}
return Energy(f / 10.0)
}
func (v Power) String() string { return fmt.Sprintf("%f W", v) }
func (v Voltage) String() string { return fmt.Sprintf("%f V", v) }
func (v Current) String() string { return fmt.Sprintf("%f A", v) }
func (v Energy) String() string { return fmt.Sprintf("%f kWh", v) }
func (v Frequency) String() string { return fmt.Sprintf("%f Hz", v) }
func (v Temp) String() string { return fmt.Sprintf("%f C", v) }
// DeviceInfo holds the static information about an inverter.
type DeviceInfo struct {
ModbusVersion int `json:"modbus_version"`
RatedPower int `json:"rated_power"`
ACOutputType int `json:"ac_output_type"`
SerialNumber string `json:"serial_number"`
ModelName string `json:"model_name"`
DSP1SWVersion int `json:"dsp1_sw_version"`
DSP2SWVersion int `json:"dsp2_sw_version"`
DSPSVNVersion int `json:"dsp_svn_version"`
ArmSWVersion int `json:"arm_sw_version"`
ArmSVNVersion int `json:"arm_svn_version"`
SoftwareVersion string `json:"software_version"`
ArmVersion string `json:"arm_version"`
SinglePhase bool `json:"single_phase"`
}
type ETRuntimeData struct {
Timestamp time.Time `json:"timestamp" db:"timestamp"`
PV1Voltage Voltage `json:"pv1_voltage" db:"pv1_voltage"`
PV1Current Current `json:"pv1_current" db:"pv1_current"`
PV1Power Power `json:"pv1_power" db:"pv1_power"`
PV2Voltage Voltage `json:"pv2_voltage" db:"pv2_voltage"`
PV2Current Current `json:"pv2_current" db:"pv2_current"`
PV2Power Power `json:"pv2_power" db:"pv2_power"`
PVPower Power `json:"pv_power" db:"pv_power"`
PV2Mode byte `json:"pv2_mode" db:"pv2_mode"`
PV1Mode byte `json:"pv1_mode" db:"pv1_mode"`
OnGridL1Voltage Voltage `json:"on_grid_l1_voltage" db:"on_grid_l1_voltage"`
OnGridL1Current Current `json:"on_grid_l1_current" db:"on_grid_l1_current"`
OnGridL1Frequency Frequency `json:"on_grid_l1_frequency" db:"on_grid_l1_frequency"`
OnGridL1Power Power `json:"on_grid_l1_power" db:"on_grid_l1_power"`
OnGridL2Voltage Voltage `json:"on_grid_l2_voltage" db:"on_grid_l2_voltage"`
OnGridL2Current Current `json:"on_grid_l2_current" db:"on_grid_l2_current"`
OnGridL2Frequency Frequency `json:"on_grid_l2_frequency" db:"on_grid_l2_frequency"`
OnGridL2Power Power `json:"on_grid_l2_power" db:"on_grid_l2_power"`
OnGridL3Voltage Voltage `json:"on_grid_l3_voltage" db:"on_grid_l3_voltage"`
OnGridL3Current Current `json:"on_grid_l3_current" db:"on_grid_l3_current"`
OnGridL3Frequency Frequency `json:"on_grid_l3_frequency" db:"on_grid_l3_frequency"`
OnGridL3Power Power `json:"on_grid_l3_power" db:"on_grid_l3_power"`
GridMode int `json:"grid_mode" db:"grid_mode"`
TotalInverterPower Power `json:"total_inverter_power" db:"total_inverter_power"`
ActivePower Power `json:"active_power" db:"active_power"`
ReactivePower int `json:"reactive_power" db:"reactive_power"`
ApparentPower int `json:"apparent_power" db:"apparent_power"`
BackupL1Voltage Voltage `json:"backup_l1_voltage" db:"backup_l1_voltage"`
BackupL1Current Current `json:"backup_l1_current" db:"backup_l1_current"`
BackupL1Frequency Frequency `json:"backup_l1_frequency" db:"backup_l1_frequency"`
LoadModeL1 int `json:"load_mode_l1" db:"load_mode_l1"`
BackupL1Power Power `json:"backup_l1_power" db:"backup_l1_power"`
BackupL2Voltage Voltage `json:"backup_l2_voltage" db:"backup_l2_voltage"`
BackupL2Current Current `json:"backup_l2_current" db:"backup_l2_current"`
BackupL2Frequency Frequency `json:"backup_l2_frequency" db:"backup_l2_frequency"`
LoadModeL2 int `json:"load_mode_l2" db:"load_mode_l2"`
BackupL2Power Power `json:"backup_l2_power" db:"backup_l2_power"`
BackupL3Voltage Voltage `json:"backup_l3_voltage" db:"backup_l3_voltage"`
BackupL3Current Current `json:"backup_l3_current" db:"backup_l3_current"`
BackupL3Frequency Frequency `json:"backup_l3_frequency" db:"backup_l3_frequency"`
LoadModeL3 int `json:"load_mode_l3" db:"load_mode_l3"`
BackupL3Power Power `json:"backup_l3_power" db:"backup_l3_power"`
LoadL1 Power `json:"load_l1" db:"load_l1"`
LoadL2 Power `json:"load_l2" db:"load_l2"`
LoadL3 Power `json:"load_l3" db:"load_l3"`
BackupLoad Power `json:"backup_load" db:"backup_load"`
Load Power `json:"load" db:"load"`
UPSLoad int `json:"ups_load" db:"ups_load"`
TemperatureAir Temp `json:"temperature_air" db:"temperature_air"`
TemperatureModule Temp `json:"temperature_module" db:"temperature_module"`
Temperature Temp `json:"temperature" db:"temperature"`
FunctionBit int `json:"-" db:"-"`
BusVoltage Voltage `json:"bus_voltage" db:"bus_voltage"`
NBusVoltage Voltage `json:"nbus_voltage" db:"nbus_voltage"`
BatteryVoltage Voltage `json:"battery_voltage" db:"battery_voltage"`
BatteryCurrent Current `json:"battery_current" db:"battery_current"`
BatteryMode int `json:"battery_mode" db:"battery_mode"`
WarningCode int `json:"warning_code" db:"warning_code"`
SafetyCountryCode int `json:"safety_country_code" db:"safety_country_code"`
WorkMode int `json:"work_mode" db:"work_mode"`
OperationCode int `json:"operation_code" db:"operation_code"`
ErrorCodes int `json:"-" db:"-"`
EnergyGenerationTotal Energy `json:"energy_generation_total" db:"energy_generation_total"`
EnergyGenerationToday Energy `json:"energy_generation_today" db:"energy_generation_today"`
EnergyExportTotal Energy `json:"energy_export_total" db:"energy_export_total"`
EnergyExportTotalHours int `json:"energy_export_total_hours" db:"energy_export_total_hours"`
EnergyExportToday Energy `json:"energy_export_today" db:"energy_export_today"`
EnergyImportTotal Energy `json:"energy_import_total" db:"energy_import_total"`
EnergyImportToday Energy `json:"energy_import_today" db:"energy_import_today"`
EnergyLoadTotal Energy `json:"energy_load_total" db:"energy_load_total"`
EnergyLoadDay Energy `json:"energy_load_day" db:"energy_load_day"`
BatteryChargeTotal int `json:"battery_charge_total" db:"battery_charge_total"`
BatteryChargeToday int `json:"battery_charge_today" db:"battery_charge_today"`
BatteryDischargeTotal int `json:"battery_discharge_total" db:"battery_discharge_total"`
BatteryDischargeToday int `json:"battery_discharge_today" db:"battery_discharge_today"`
DiagStatusCode int `json:"-" db:"-"`
HouseConsumption Power `json:"house_consumption" db:"house_consumption"`
}
type ETMeterData struct {
ComMode int `json:"com_mode" db:"-"`
RSSI int `json:"-" db:"-"`
ManufactureCode int `json:"manufacture_code" db:"-"`
MeterTestStatus int `json:"meter_test_status" db:"meter_test_status"`
MeterCommStatus int `json:"meter_comm_status" db:"meter_comm_status"`
ActivePowerL1 Power `json:"active_power_l1" db:"active_power_l1"`
ActivePowerL2 Power `json:"active_power_l2" db:"active_power_l2"`
ActivePowerL3 Power `json:"active_power_l3" db:"active_power_l3"`
ActivePowerTotal Power `json:"active_power_total" db:"active_power_total"`
ReactivePowerTotal int `json:"reactive_power_total" db:"reactive_power_total"`
MeterPowerFactor1 float64 `json:"meter_power_factor1" db:"meter_power_factor1"`
MeterPowerFactor2 float64 `json:"meter_power_factor2" db:"meter_power_factor2"`
MeterPowerFactor3 float64 `json:"meter_power_factor3" db:"meter_power_factor3"`
MeterPowerFactor float64 `json:"meter_power_factor" db:"meter_power_factor"`
MeterFrequency Frequency `json:"meter_frequency" db:"meter_frequency"`
EnergyExportTotal Power `json:"meter_energy_export_total" db:"meter_energy_export_total"`
EnergyImportTotal Power `json:"meter_energy_import_total" db:"meter_energy_import_total"`
MeterActivePower1 Power `json:"meter_active_power1" db:"meter_active_power1"`
MeterActivePower2 Power `json:"meter_active_power2" db:"meter_active_power2"`
MeterActivePower3 Power `json:"meter_active_power3" db:"meter_active_power3"`
MeterActivePowerTotal Power `json:"meter_active_power_total" db:"meter_active_power_total"`
MeterReactivePower1 int `json:"meter_reactive_power1" db:"meter_reactive_power1"`
MeterReactivePower2 int `json:"meter_reactive_power2" db:"meter_reactive_power2"`
MeterReactivePower3 int `json:"meter_reactive_power3" db:"meter_reactive_power3"`
MeterReactivePowerTotal int `json:"meter_reactive_power_total" db:"meter_reactive_power_total"`
MeterApparentPower1 int `json:"meter_apparent_power1" db:"meter_apparent_power1"`
MeterApparentPower2 int `json:"meter_apparent_power2" db:"meter_apparent_power2"`
MeterApparentPower3 int `json:"meter_apparent_power3" db:"meter_apparent_power3"`
MeterApparentPowerTotal int `json:"meter_apparent_power_total" db:"meter_apparent_power_total"`
MeterType int `json:"meter_type" db:"-"`
MeterSoftwareVersion int `json:"meter_software_version" db:"meter_software_version"`
}
type ETDataFrame struct {
*ETRuntimeData
*ETMeterData
}